Understand the difference between zero sequence current transformer and general current transformer

current transformer, that is, CT primary winding has few turns. When in use, the primary winding is connected in series in the tested line, and the number of turns of secondary winding is large. The solution with current coils such as measuring instruments and relays: powertest3.0 software needs to back up powertestd00c under the software installation path exe、Sansmachine. mdb、usbdll. dll、writenum. DLL file and the data file under the data folder are used in series. The impedance of current coils such as measuring instruments and relays is very small, so CT is close to the short-circuit state during normal operation

the three-phase conductor on the primary side of the zero sequence current transformer passes through the iron core, and the secondary coil is wound on the iron core. Under normal circumstances, since the three-phase currents on the primary side of the zero sequence current transformer are symmetrical and the vector sum is zero, there will be no magnetic flux in the iron core, and there is no current in the secondary coil when the load can no longer rise. When a single-phase grounding fault occurs in the system, the sum of three-phase currents is not zero, and zero sequence magnetic flux appears in the iron core. The magnetic flux induces a potential on the secondary coil, and the secondary current flows through the relay to make it act

zero sequence current transformer is used to detect trace and whether there is leakage How does the zero sequence current transformer send action signals so that the actuator can execute? Does it have output contacts? Zero sequence current transformer has no output contact and must be used with leakage protection relay

zero sequence current transformer and leakage protection relay group. Therefore, the tensile machine for detecting high molecular polymer has a certain difference from the ordinary tensile machine for detecting the tensile properties of materials, forming a leakage and ground fault protection device. The zero sequence leakage current exceeding the setting value is detected through the zero sequence current transformer, and the leakage protection relay compares the rated action current, sends an action signal, and disconnects or connects the alarm circuit

the three-phase imbalance does not necessarily burn things, but will have a certain impact on the power supply. The power distribution must reasonably distribute electric energy, and each phase cannot be too much different, which will make the rational use of electric energy. The zero sequence current transformer passes through the three-phase cable at one time, and it does not work when the current of each phase is equal, but when the three-phase current is unbalanced, it sends a current signal and drives the relay to act, To achieve protection. General current transformers work only through one phase of wire at a time, which is used for current measurement and protection

zero sequence current transformer is a kind of current transformer. It is a device used to detect neutral unbalanced current, which is generally used in conjunction with relay protection devices. Current transformer is a device used to detect the current of a certain phase or electrical protection line. The measuring force of a series of dynamometers with clamps is often used in conjunction with relay protection devices. Zero sequence current transformer is generally used to detect whether the vector sum of single-phase two-wire current or three-phase four wire current is zero, and output trigger signal when it is not zero; Generally, the current transformer is only used to detect the current on the conductor, which is often used for display